EKL6-63EV Type EV (A+DC6mA) RCCB Residual Current Breaker specifically designed for EV charging systems

The ETEK Type EV RCD EKL6-63EV is a cost-effective solution that combines the functionality of a Type A RCCB with a 6mA DC sensor. This device is specifically designed for EV charging systems and meets the residual current devices request by IEC 61851-1 & IEC 60364-7-722.

● Standard: IEC61008-1, IEC61008-2, IEC62955
● Classification of RDC-DD: RDC-PD
● Behaviour in Presence of d.c. Components: Type A
● Rated current: 16~63A
● Rated voltage: 230/400V~240/415V
● Poles: 2P(1P+N), 4P(3P+N), N Pole on left
● Rated Residual Operating Current (IΔn): 30mA
● Rated DC Residual Operating Current (IΔdc): 6mA
● Ambient air temperature: -25...+55 ºC
● Connection: From top and bottom
● Certificates: CE, CB, TUV, UKCA

Inquire NOW PDF

EKL6-63EV Type EV (A+DC6mA) RCCB Residual Current Breaker specifically designed for EV charging systems

Inquire NOW PDF

Porduct Overview

The ETEK Type EV RCD EKL6-63EV is a cost-effective solution that combines the functionality of a Type A RCCB with a 6mA DC sensor. This device is specifically designed for EV charging systems and meets the residual current devices request by IEC 61851-1 & IEC 60364-7-722. The compact design of the Type EV RCD integrates both AC 30mA (A Type) and 6 mA DC residual current protection. Additionally, the device is compliant with Type-A RCCB and RDC-DD (Residual Direct Current Detecting Device) standards as defined by IEC 62955.

These RCDs may only be used for protection when charging electric vehicles in line. They may not be used for any other applications. Of course, it is also possible to use Type B RCD in EV charging applications.

EV Type RCD may not be used as a replacement for Type B under any circumstances. It only detects Type A residual currents (AC and pulsating residual currents at the rated frequency of 50 Hz), as well as smooth DC residual currents (switch-off at max. 6 mA) thanks to the integrated additional function.

 

Technical parameters

Technical Data

Standard
IEC61008-1,IEC61008-2, IEC62955
Protection
Ground fault
Type of trip
Electro-magnetic
Type of protection (electric leakage)
A
No. of poles
2P(1P+N), 4P(3P+N), N Pole on left
Rated current In 25,40,63A
Rated voltage Ue 2P 240V~,4P 415V~
Rated frequency 50/60Hz
Rated sensitivity currents IΔn
30mA
DC tripping threshold (IΔdc) 6mA
Residual current off-time under I△n
≤0.1s
Rated residual making and breaking capacity (I△m) 500A(In≤40A), 10In (In>40A)
Rated breaking capacity
10,000A
SCPD fuse 10kA
Rated impulse withstands voltage (1.5/50) Uimp 4000V
Dielectric test voltage at ind. Freq. for 1min 2.5kV
Electrical life 2,000 Cycles
Mechanical life 4,000 Cycles
Contact position indicator Yes
Ground fault indicator
Yes
Protection degree IP20
Ambient temperature
-25℃ to 55℃, Max.95% humidity
Terminal connection type Cable/Pin-type busbar/U-type busbar
Max. terminal size for cable
35mm2
Max. tightening torque 2.5Nm
Installation
Mounting on 35mm DIN rail
Connection
From top and bottom

Dimensions

Circuit Diagram

ekl6-63ev-circuit-diagram

Installation size

ekl6-63ev-rccb-size

Product selection form

Poles Rated Current (A) Reference No. Specification
1P+N 16A EKL6-63EV-1N1630AD6 RCCB 10KA 1P+N 16A 30mA Type A DC 6mA
25A EKL6-63EV-1N2530AD6 RCCB 10KA 1P+N 25A 30mA Type A DC 6mA
32A EKL6-63EV-1N3230AD6 RCCB 10KA 1P+N 32A 30mA Type A DC 6mA
40A EKL6-63EV-1N4030AD6 RCCB 10KA 1P+N 40A 30mA Type A DC 6mA
63A EKL6-63EV-1N6330AD6 RCCB 10KA 1P+N 63A 30mA Type A DC 6mA
3P+N 16A EKL6-63EV-3N1630AD6 RCCB 10KA 3P+N 16A 30mA Type A DC 6mA
25A EKL6-63EV-3N2530AD6 RCCB 10KA 3P+N 25A 30mA Type A DC 6mA
32A EKL6-63EV-3N3230AD6 RCCB 10KA 3P+N 32A 30mA Type A DC 6mA
40A EKL6-63EV-3N4030AD6 RCCB 10KA 3P+N 40A 30mA Type A DC 6mA
63A EKL6-63EV-3N6330AD6 RCCB 10KA 3P+N 63A 30mA Type A DC 6mA

Download Files

Porduct Overview

The ETEK Type EV RCD EKL6-63EV is a cost-effective solution that combines the functionality of a Type A RCCB with a 6mA DC sensor. This device is specifically designed for EV charging systems and meets the residual current devices request by IEC 61851-1 & IEC 60364-7-722. The compact design of the Type EV RCD integrates both AC 30mA (A Type) and 6 mA DC residual current protection. Additionally, the device is compliant with Type-A RCCB and RDC-DD (Residual Direct Current Detecting Device) standards as defined by IEC 62955.

These RCDs may only be used for protection when charging electric vehicles in line. They may not be used for any other applications. Of course, it is also possible to use Type B RCD in EV charging applications.

EV Type RCD may not be used as a replacement for Type B under any circumstances. It only detects Type A residual currents (AC and pulsating residual currents at the rated frequency of 50 Hz), as well as smooth DC residual currents (switch-off at max. 6 mA) thanks to the integrated additional function.

 