EKL4-40S 6KA magnetic type RCBO
EKL4-40S 6KA magnetic type RCBO
EKL4-40S 6KA magnetic type RCBO

EKL4-40S RCBO 4.5KA Residual Current Operated Circuit Breaker

Mode: Electronic; Type: AC, A; Rated current In: 6,8,10,13,16,20,25,32,40A; Poles: 1P+N; Rated voltage Ue: 240V~; Insulation voltage Ui: 500V; Rated frequency: 50/60Hz; Rated residual operating current (I△n): 10,30,100,300mA

Inquire NOW PDF

EKL4-40S RCBO 4.5KA Residual Current Operated Circuit Breaker

Inquire NOW PDF

Product Profile

EKL4-40S 1P+N magnetic type RCBO provides protection against earth faults, overloads, short circuits and over-voltage in commercial and domestic installation. The RCBO with both disconnected neutral and phase guarantees its proper actuation against earth leakage faults even when the neutral and phase are wrongly connected the electronic RCBO incorporate a filtering device preventing the risks of unwanted due to transient voltages and transient currents.

Technical Data

Standard IEC/EN61009-1
Protection Ground fault, Overcurrent and short circuit
Type of trip Ground fault: Electronic
Overload and short circuit: Thermo-magnetic
No. of poles 1P+N, 1module, N line with disconnected
Type AC, A
Rated current In 6,10,16,20,25,32,40A
Rated voltage Ue 240V~
Insulation voltage Ui 500V
Rated frequency 50/60Hz
Rated residual operating current(I△n)

10,30mA

Break time under I△n ≤0.1s
Rated breaking capacity 4,500A, 6,000A
Rated impulse withstand voltage (1.2/50) Uimp 4,000V
Dielectric test voltage at ind.Freq. for 1min 2kV
Thermo-magnetic release characteristic B:(3-5) x In, C:(5-10) x In
Electrical life 4,000 Cycles
Mechanical life 10,000 Cycles
Contact position indicator Yes
Ambient temperature -25℃~+40℃, Max.95% humidity
Terminal connection type Cable/Pin-type busbar
Max. terminal size for cable 16mm2
Max. tightening torque 2.5N.m
Installation Mounting on 35mm DIN rail
Connection From to top

Dimensions

Circuit Diagram

 

 

Installation Size

 

Product selection form

Poles Rated Current(A) B Curve
Sensitivity
10mA 30mA
Type AC
1P+N 6A EKL4-40S-1NB0610 EKL4-40S-1NB0630
10A EKL4-40S-1NB1010 EKL4-40S-1NB1030
16A EKL4-40S-1NB1610 EKL4-40S-1NB1630
20A EKL4-40S-1NB2010 EKL4-40S-1NB2030
25A EKL4-40S-1NB2510 EKL4-40S-1NB2530
32A EKL4-40S-1NB3210 EKL4-40S-1NB3230
40A EKL4-40S-1NB4010 EKL4-40S-1NB4030
  Type A
6A EKL4-40S-1NB0610A EKL4-40S-1NB0630A
10A EKL4-40S-1NB1010A EKL4-40S-1NB1030A
16A EKL4-40S-1NB1610A EKL4-40S-1NB1630A
20A EKL4-40S-1NB2010A EKL4-40S-1NB2030A
25A EKL4-40S-1NB2510A EKL4-40S-1NB2530A
32A EKL4-40S-1NB3210A EKL4-40S-1NB3230A
40A EKL4-40S-1NB4010A EKL4-40S-1NB4030A
Rated Current(A) C Curve
Sensitivity
10mA 30mA
Type AC
6A EKL4-40S-1NC0610 EKL4-40S-1NC0630
10A EKL4-40S-1NC1010 EKL4-40S-1NC1030
16A EKL4-40S-1NC1610 EKL4-40S-1NC1630
20A EKL4-40S-1NC2010 EKL4-40S-1NC2030
25A EKL4-40S-1NC2510 EKL4-40S-1NC2530
32A EKL4-40S-1NC3210 EKL4-40S-1NC3230
40A EKL4-40S-1NC4010 EKL4-40S-1NC4030
  Type A
6A EKL4-40S-1NC0610A EKL4-40S-1NC0630A
10A EKL4-40S-1NC1010A EKL4-40S-1NC1030A
16A EKL4-40S-1NC1610A EKL4-40S-1NC1630A
20A EKL4-40S-1NC2010A EKL4-40S-1NC2030A
25A EKL4-40S-1NC2510A EKL4-40S-1NC2530A
32A EKL4-40S-1NC3210A EKL4-40S-1NC3230A
40A EKL4-40S-1NC4010A EKL4-40S-1NC4030A

Product Profile

EKL4-40S 1P+N magnetic type RCBO provides protection against earth faults, overloads, short circuits and over-voltage in commercial and domestic installation. The RCBO with both disconnected neutral and phase guarantees its proper actuation against earth leakage faults even when the neutral and phase are wrongly connected the electronic RCBO incorporate a filtering device preventing the risks of unwanted due to transient voltages and transient currents.

Technical Data

Dimensions

Product selection form

Recommend Products

Recommend Products

Send An Inquiry

Get in Touch

×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All