EKL4-40S 1P+N magnetic type RCBO provides protection against earth faults, overloads, short circuits and over-voltage in commercial and domestic installation. The RCBO with both disconnected neutral and phase guarantees its proper actuation against earth leakage faults even when the neutral and phase are wrongly connected the electronic RCBO incorporate a filtering device preventing the risks of unwanted due to transient voltages and transient currents.
Standard | IEC/EN61009-1 | ||
Protection | Ground fault, Overcurrent and short circuit | ||
Type of trip | Ground fault: Electronic | ||
Overload and short circuit: Thermo-magnetic | |||
No. of poles | 1P+N, 1module, N line with disconnected | ||
Type | AC, A | ||
Rated current In | 6,10,16,20,25,32,40A | ||
Rated voltage Ue | 240V~ | ||
Insulation voltage Ui | 500V | ||
Rated frequency | 50/60Hz | ||
Rated residual operating current(I△n) |
10,30mA |
||
Break time under I△n | ≤0.1s | ||
Rated breaking capacity | 4,500A, 6,000A | ||
Rated impulse withstand voltage (1.2/50) Uimp | 4,000V | ||
Dielectric test voltage at ind.Freq. for 1min | 2kV | ||
Thermo-magnetic release characteristic | B:(3-5) x In, C:(5-10) x In | ||
Electrical life | 4,000 Cycles | ||
Mechanical life | 10,000 Cycles | ||
Contact position indicator | Yes | ||
Ambient temperature | -25℃~+40℃, Max.95% humidity | ||
Terminal connection type | Cable/Pin-type busbar | ||
Max. terminal size for cable | 16mm2 | ||
Max. tightening torque | 2.5N.m | ||
Installation | Mounting on 35mm DIN rail | ||
Connection | From to top |
Poles | Rated Current(A) | B Curve | |
Sensitivity | |||
10mA | 30mA | ||
Type AC | |||
1P+N | 6A | EKL4-40S-1NB0610 | EKL4-40S-1NB0630 |
10A | EKL4-40S-1NB1010 | EKL4-40S-1NB1030 | |
16A | EKL4-40S-1NB1610 | EKL4-40S-1NB1630 | |
20A | EKL4-40S-1NB2010 | EKL4-40S-1NB2030 | |
25A | EKL4-40S-1NB2510 | EKL4-40S-1NB2530 | |
32A | EKL4-40S-1NB3210 | EKL4-40S-1NB3230 | |
40A | EKL4-40S-1NB4010 | EKL4-40S-1NB4030 | |
Type A | |||
6A | EKL4-40S-1NB0610A | EKL4-40S-1NB0630A | |
10A | EKL4-40S-1NB1010A | EKL4-40S-1NB1030A | |
16A | EKL4-40S-1NB1610A | EKL4-40S-1NB1630A | |
20A | EKL4-40S-1NB2010A | EKL4-40S-1NB2030A | |
25A | EKL4-40S-1NB2510A | EKL4-40S-1NB2530A | |
32A | EKL4-40S-1NB3210A | EKL4-40S-1NB3230A | |
40A | EKL4-40S-1NB4010A | EKL4-40S-1NB4030A | |
Rated Current(A) | C Curve | ||
Sensitivity | |||
10mA | 30mA | ||
Type AC | |||
6A | EKL4-40S-1NC0610 | EKL4-40S-1NC0630 | |
10A | EKL4-40S-1NC1010 | EKL4-40S-1NC1030 | |
16A | EKL4-40S-1NC1610 | EKL4-40S-1NC1630 | |
20A | EKL4-40S-1NC2010 | EKL4-40S-1NC2030 | |
25A | EKL4-40S-1NC2510 | EKL4-40S-1NC2530 | |
32A | EKL4-40S-1NC3210 | EKL4-40S-1NC3230 | |
40A | EKL4-40S-1NC4010 | EKL4-40S-1NC4030 | |
Type A | |||
6A | EKL4-40S-1NC0610A | EKL4-40S-1NC0630A | |
10A | EKL4-40S-1NC1010A | EKL4-40S-1NC1030A | |
16A | EKL4-40S-1NC1610A | EKL4-40S-1NC1630A | |
20A | EKL4-40S-1NC2010A | EKL4-40S-1NC2030A | |
25A | EKL4-40S-1NC2510A | EKL4-40S-1NC2530A | |
32A | EKL4-40S-1NC3210A | EKL4-40S-1NC3230A | |
40A | EKL4-40S-1NC4010A | EKL4-40S-1NC4030A |
EKL4-40S 1P+N magnetic type RCBO provides protection against earth faults, overloads, short circuits and over-voltage in commercial and domestic installation. The RCBO with both disconnected neutral and phase guarantees its proper actuation against earth leakage faults even when the neutral and phase are wrongly connected the electronic RCBO incorporate a filtering device preventing the risks of unwanted due to transient voltages and transient currents.