EKL1-63B Type B RCD has novel appearance design, compact structure, good reliability, and high safety. The products comply with IEC61008-1, IEC62423 and other standards, and the product certification is complete; Hey ensure higher protection levels with maximum operational continuity under all working conditions. For this reason, Type B RCDs are considered universal devices because they provide protection against all the tripping waveforms listed in the Standards EN 62423.Type B RCDs can ensure maximum safety in many applications, such as EV Charging Station, Crane and Elevator and Wind power Plantses.
RCCB Electrical Features |
||
| Mode | Electromagnetic | |
| Type (wave form of the earth leakage sensed) | B | |
| Rated current In | 25,40,63A | |
| Poles | 2P(1P+N), 4P(3P+N) | |
| Rated voltage Ue | 2P 240V~,4P 415V~ | |
| Insulation voltage Ui | 500V | |
| Rated frequency | 50/60Hz | |
| Rated residual operation current(I△n) | 30mA, 100mA, 300mA, 500mA | |
| Rated residual making and breaking capacity (I△m) | 500A(In≤40A), 10In (In>40A) | |
| Short-circuit current Inc= I△c | 10,000A | |
| SCPD fuse | ![]() |
|
| Break time under I△n | ≤0.1s | |
| Rated impulse withstands voltage (1.5/50) Uimp | 4000V | |
| Dielectric test voltage at ind.Freq. for 1min | 2.5kV | |
| Electrical life | 2,000 Cycles | |
| Mechanical life | 4,000 Cycles | |
RCCB Installation |
||
| Contact position indicator | Yes | |
| Protection degree | IP20 | |
| Ambient temperature (with daily average≤35℃) | -5℃~+40℃ | |
| Storage temperature | -25℃~+70℃ | |
| Terminal connection type | Cable/Pin-type busbar/U-type busbar | |
| Terminal size top/bottom for cable | 25mm2 18-3AWG | |
| Terminal size top/bottom for busbar | 25mm2 18-3AWG | |
| Tightening torque | 2.5Nm 22In-lbs | |
| Mounting | On DIN rail EN60715(35mm) by means of a fast clip device | |
| Connection | Power supply in both directions | |
Tripping Current Range |
||
| Lagging Angle | I△n>0.01A | I△n≤0.01A |
| 0° | 0.35I△n≤I△≤1.4I△n | 0.35I△n≤I△≤2I△n |
| 90° | 0.25I△n≤I△≤1.4I△n | 0.25I△n≤I△≤2I△n |
| 135° | 0.11I△n≤I△≤1.4I△n | 0.11I△n≤I△≤2I△n |


| Poles | Rated Current (A) | Sensitivity | |||
| 30mA | 100mA | 300mA | 500mA | ||
| 1P+N | 25A | EKL1-63B-1N2530 | EKL1-63B-1N25100 | EKL1-63B-1N25300 | EKL1-63B-1N25500 |
| 40A | EKL1-63B-1N4030 | EKL1-63B-1N40100 | EKL1-63B-1N40300 | EKL1-63B-1N40500 | |
| 63A | EKL1-63B-1N6330 | EKL1-63B-1N63100 | EKL1-63B-1N63300 | EKL1-63B-1N63500 | |
| 3P+N | 25A | EKL1-63B-3N2530 | EKL1-63B-3N25100 | EKL1-63B-3N25300 | EKL1-63B-3N25500 |
| 40A | EKL1-63B-3N4030 | EKL1-63B-3N40100 | EKL1-63B-3N40300 | EKL1-63B-3N40500 | |
| 63A | EKL1-63B-3N6330 | EKL1-63B-3N63100 | EKL1-63B-3N63300 | EKL1-63B-3N63500 | |

EKL1-63B Type B RCD has novel appearance design, compact structure, good reliability, and high safety. The products comply with IEC61008-1, IEC62423 and other standards, and the product certification is complete; Hey ensure higher protection levels with maximum operational continuity under all working conditions. For this reason, Type B RCDs are considered universal devices because they provide protection against all the tripping waveforms listed in the Standards EN 62423.Type B RCDs can ensure maximum safety in many applications, such as EV Charging Station, Crane and Elevator and Wind power Plantses.