● Standard: IEC61009-1
● Type: AC, A
● Rated current: 6~40A
● Rated voltage: 230/240~
● Number of poles: Two Poles
● Rated Residual Operating Current (IAn): 10, 30, 100, 300mA
● Rated short-circuit breaking capacity: 6kA, 10kA
● Tripping curve: B, C
● Ambient air temperature: -25...+40 ºC
● Certificates: CE, CB, UKCA, SAA
EKL9-40 products provide protection against earth faults, overloads, short circuits and over-voltage in commercial and domestic installation. The RCBO with both disconnected neutral and phase guarantees its proper actuation against earth leakage faults even when the neutral and phase are wrongly connected the electronic RCBO incorporate a filtering device preventing the risks of unwanted due to transient voltages and transient currents.
This is RCBO can be wired from the bottom and top.
Provides protection against earth fault/leakage current and function of isolation.
High short-circuits current withstand capacity.
Applicable to terminal and pin/fork type busbar connection.
Equipped with finger protected connection terminals.
Fire resistant plastic parts endure abnormal heating and strong impact.
Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.
Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
Rated current can reach up to 40A.
Standard | IEC/EN61009-1 | ||
Protection
|
Ground fault, Overcurrent and short circuit
|
||
Type of trip
|
Ground fault: Electronic
|
||
Overload and short circuit: Thermo-magnetic
|
|||
No. of poles
|
1P+N,1 Module, N line with disconnected
|
||
Type | AC, A | ||
Rated current In | 6,10,16,20,25,32,40A | ||
Rated sensitivity currents I△n
|
10,30,100,300mA | ||
Residual current off-time under I△n | ≤0.1s | ||
Reted residual making and breaking capacity (I△m) | 500A(In≤50A),10In (In>50A) | ||
Rated voltage Ue | 240V~ | ||
Rated frequency | 50/60Hz | ||
Rated breaking capacity | 6kA,10kA | ||
Energy limiting class | 3 | ||
Rated impulse withstands voltage (1.5/50) Uimp | 4,000V | ||
Dielectric test voltage at ind.Freq. for 1min | 2kV | ||
Thermal release characteristic
|
(1.13-1.45) x In
|
||
Magnetic release characteristic |
B:(3-5) x In, C:(5-10) x In
|
||
Electrical life | 4,000 Cycles | ||
Mechanical life | 10,000 Cycles | ||
Contact position indicator | Yes | ||
Protection degree | IP20 | ||
Ambient temperature | -25℃~+40℃, Max.95% humidity | ||
Terminal connection type | Cable/Pin-type busbar | ||
Max. terminal size for cable
|
16mm2 | ||
Max. tightening torque | 2.5N.m | ||
Installation
|
Mounting on 35mm DIN rail
|
||
Connection |
From top and bottom
|
Poles | Rated Current(A) | B Curve | |||
Sensitivity | |||||
10mA | 30mA | 100mA | 300mA | ||
Type AC | |||||
1P+N | 6A | EKL9-40-1NB0610 | EKL9-40-1NB0630 | EKL9-40-1NB06100 | EKL9-40-1NB06300 |
10A | EKL9-40-1NB1010 | EKL9-40-1NB1030 | EKL9-40-1NB10100 | EKL9-40-1NB10300 | |
16A | EKL9-40-1NB1610 | EKL9-40-1NB1630 | EKL9-40-1NB16100 | EKL9-40-1NB16300 | |
20A | EKL9-40-1NB2010 | EKL9-40-1NB2030 | EKL9-40-1NB20100 | EKL9-40-1NB20300 | |
25A | EKL9-40-1NB2510 | EKL9-40-1NB2530 | EKL9-40-1NB25100 | EKL9-40-1NB25300 | |
32A | EKL9-40-1NB3210 | EKL9-40-1NB3230 | EKL9-40-1NB32100 | EKL9-40-1NB32300 | |
40A | EKL9-40-1NB4010 | EKL9-40-1NB4030 | EKL9-40-1NB40100 | EKL9-40-1NB40300 | |
Type A | |||||
6A | EKL9-40-1NB0610A | EKL9-40-1NB0630A | EKL9-40-1NB06100A | EKL9-40-1NB06300A | |
10A | EKL9-40-1NB1010A | EKL9-40-1NB1030A | EKL9-40-1NB10100A | EKL9-40-1NB10300A | |
16A | EKL9-40-1NB1610A | EKL9-40-1NB1630A | EKL9-40-1NB16100A | EKL9-40-1NB16300A | |
20A | EKL9-40-1NB2010A | EKL9-40-1NB2030A | EKL9-40-1NB20100A | EKL9-40-1NB20300A | |
25A | EKL9-40-1NB2510A | EKL9-40-1NB2530A | EKL9-40-1NB25100A | EKL9-40-1NB25300A | |
32A | EKL9-40-1NB3210A | EKL9-40-1NB3230A | EKL9-40-1NB32100A | EKL9-40-1NB32300A | |
40A | EKL9-40-1NB4010A | EKL9-40-1NB4030A | EKL9-40-1NB40100A | EKL9-40-1NB40300A | |
Rated Current(A) | C Curve | ||||
Sensitivity | |||||
10mA | 30mA | 100mA | 300mA | ||
Type AC | |||||
6A | EKL9-40-1NC0610 | EKL9-40-1NC0630 | EKL9-40-1NC06100 | EKL9-40-1NC06300 | |
10A | EKL9-40-1NC1010 | EKL9-40-1NC1030 | EKL9-40-1NC10100 | EKL9-40-1NC10300 | |
16A | EKL9-40-1NC1610 | EKL9-40-1NC1630 | EKL9-40-1NC16100 | EKL9-40-1NC16300 | |
20A | EKL9-40-1NC2010 | EKL9-40-1NC2030 | EKL9-40-1NC20100 | EKL9-40-1NC20300 | |
25A | EKL9-40-1NC2510 | EKL9-40-1NC2530 | EKL9-40-1NC25100 | EKL9-40-1NC25300 | |
32A | EKL9-40-1NC3210 | EKL9-40-1NC3230 | EKL9-40-1NC32100 | EKL9-40-1NC32300 | |
40A | EKL9-40-1NC4010 | EKL9-40-1NC4030 | EKL9-40-1NC40100 | EKL9-40-1NC40300 | |
Type A | |||||
6A | EKL9-40-1NC0610A | EKL9-40-1NC0630A | EKL9-40-1NC06100A | EKL9-40-1NC06300A | |
10A | EKL9-40-1NC1010A | EKL9-40-1NC1030A | EKL9-40-1NC10100A | EKL9-40-1NC10300A | |
16A | EKL9-40-1NC1610A | EKL9-40-1NC1630A | EKL9-40-1NC16100A | EKL9-40-1NC16300A | |
20A | EKL9-40-1NC2010A | EKL9-40-1NC2030A | EKL9-40-1NC20100A | EKL9-40-1NC20300A | |
25A | EKL9-40-1NC2510A | EKL9-40-1NC2530A | EKL9-40-1NC25100A | EKL9-40-1NC25300A | |
32A | EKL9-40-1NC3210A | EKL9-40-1NC3230A | EKL9-40-1NC32100A | EKL9-40-1NC32300A | |
40A | EKL9-40-1NC4010A | EKL9-40-1NC4030A | EKL9-40-1NC40100A | EKL9-40-1NC40300A |
EKL9-40 products provide protection against earth faults, overloads, short circuits and over-voltage in commercial and domestic installation. The RCBO with both disconnected neutral and phase guarantees its proper actuation against earth leakage faults even when the neutral and phase are wrongly connected the electronic RCBO incorporate a filtering device preventing the risks of unwanted due to transient voltages and transient currents.
This is RCBO can be wired from the bottom and top.
Provides protection against earth fault/leakage current and function of isolation.
High short-circuits current withstand capacity.
Applicable to terminal and pin/fork type busbar connection.
Equipped with finger protected connection terminals.
Fire resistant plastic parts endure abnormal heating and strong impact.
Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.
Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
Rated current can reach up to 40A.